XGN2-12 Кільцевий головний блок (RMU)

Introduction to XGN2-12 Ring Main Unit

In modern electrical distribution systems, Кільцеві головні блоки (RMU) play a crucial role in ensuring network reliability and operational efficiency. The XGN2-12 Кільцевий головний блок (RMU) is a high-performance, metal-enclosed, and air-insulated розподільчі пристрої solution specifically designed for medium-voltage distribution applications up to 12kV. It is engineered to meet the highest standards of safety, stability, and flexibility, offering robust performance in a wide variety of environments.

Applications of XGN2-12 Ring Main Unit

The XGN2-12 RMU is widely utilized in the following sectors:

  • Urban and Rural Power Distribution Networks
  • Industrial and Mining Enterprises
  • Transportation Infrastructure (Airports, Railways, Subways)
  • Renewable Energy Projects (Wind and Solar Farms)
  • Commercial Complexes and Data Centers

Its compact design, coupled with modular flexibility, makes it an ideal choice for locations where space, operational safety, and maintenance accessibility are critical.

According to IEEE and IEEMA reports, the global demand for medium-voltage switchgear is steadily growing, driven by urbanization, renewable energy integration, and modernization of aging grids. RMUs like the XGN2-12 are preferred in modern networks because they provide decentralized control, faster fault management, and seamless integration into smart grid architectures (джерело).

As digitalization and grid automation increase, the importance of compact, reliable RMUs in distribution systems has never been greater.

Technical Specifications of XGN2-12 RMU

The XGN2-12 series demonstrates superior technical capabilities:

ПунктОдиницяXGN15-12(F) / 630-20XGN15-12(F.R)/T125-31.5
Номінальна напругакВ1212
Номінальний струмA630125
Номінальна частотаГц5050
Rated Frequency Withstand VoltageкВ42/4842/48
Rated Impulse Withstand VoltageкВ75/8575/85
Rated Active Load Breaking CurrentA630-
Closed-Loop Distribution Circuit CurrentA630-
Short-Circuit Making Current (Peak)кА5080
Піковий витримуваний струмкА5050
Short-Time Withstand CurrentкА2020
Short Circuit Durations44
Rated SF₆ Gas Pressure (20°C)MPa0.040.04
Loop ResistanceµΩ≤200≤400
Mechanical Endurance (LBS/Earthing)Cycles5000/30005000/3000
Short-Circuit Breaking CurrentкА20/5031.5/50
Transfer CurrentA-1750
Ступінь захистуIP4XIP4X
Technical specifications table for XGN2-12 Ring Main Unit

Ключові особливості та переваги

  • Compact Size and Modular Design: Enables flexible layouts and easy system expansions.
  • High Operational Safety: Achieves IP4X protection level, ensuring personnel and system safety.
  • Reliable Performance: Capable of withstanding high fault currents with robust mechanical endurance.
  • Eco-Friendly: Air insulation eliminates the need for heavy SF₆ gas reliance compared to GIS alternatives.
  • Ease of Maintenance: Front-accessible operations and simplified maintenance procedures.

Порівняння з іншими типами розподільчих пристроїв

ОсобливістьMetal-Clad Switchgear (e.g., KYN28-24)Ring Main Unit (XGN2-12)Gas-Insulated Switchgear (e.g., SRM6-12)
Ізоляційне середовищеПовітряПовітряSF₆ Газ
FootprintБільший.КомпактнийДуже компактний
Typical ApplicationPrimary DistributionВторинна дистрибуціяHarsh/Space-Constrained Sites
Потреби в технічному обслуговуванніHigherLowerДуже низький
Comparison of Metal-Clad, Ring Main Unit, and Gas-Insulated Switchgear types

Поради щодо вибору та купівлі

When selecting an RMU like the XGN2-12, consider the following:

  • System Voltage and Current Requirements
  • Space Constraints at Installation Site
  • Expected Fault Current Levels
  • Automation and Remote Monitoring Needs
  • Compliance with Local Standards (e.g., IEC 62271-200)

For large-scale projects or special environmental conditions, consulting technical experts at PINEELE can ensure optimal configuration and long-term performance.

Часті запитання (FAQ)

1. What is the rated voltage and current for the XGN2-12 RMU?

The XGN2-12 RMU supports a rated voltage of 12kV and rated currents typically up to 630A, depending on specific configuration models.

2. Can the XGN2-12 RMU be integrated into smart grid systems?

Yes, it is designed for smart grid compatibility with provisions for remote monitoring, SCADA integration, and automation enhancements.

3. What maintenance is required for the XGN2-12 Ring Main Unit?

Maintenance is minimal due to its robust construction. Routine inspections, mechanical checks, and cleaning of insulators are usually sufficient to ensure long-term reliability.

By combining innovation, engineering expertise, and a strong commitment to quality, PINEELE’s XGN2-12 Ring Main Unit is a proven solution for modern medium-voltage networks.

Високовольтна компенсаційна шафа TBB

Зміст Розуміння основної концепції Застосування в сучасних електричних мережах Технічні характеристики Галузеві тенденції та технологічна еволюція Чим відрізняється від інших продуктів

Читати далі "

Розподільні пристрої з металевим корпусом GTXGN-12

Зміст Вступ до розподільчого пристрою з металевим корпусом GTXGN-12 Застосування розподільчого пристрою GTXGN-12 Тенденції ринку розподільчих пристроїв GTXGN-12 та основні технічні характеристики GTXGN-12 Ключові особливості та переваги Порівняння

Читати далі "

Головний блок кільця XGN66-12

Зміст Вступ до кільцевого головного блоку XGN66-12 Застосування XGN66-12 RMU Ринкові тенденції та основні технічні характеристики кільцевого головного блоку XGN66-12 Параметри кільцевого головного блоку XGN66-12

Читати далі "

Розподільчий пристрій з елегазовою ізоляцією SRM6-12

Зміст Вступ до КРПЕ з елегазовою ізоляцією SRM6-12 Застосування КРПЕ з елегазовою ізоляцією SRM6-12 Тенденції ринку КРПЕ з елегазовою ізоляцією та основні технічні характеристики КРПЕ з елегазовою ізоляцією SRM6-12 Ключові особливості та переваги Порівняння

Читати далі "

KYN28-24 Розподільчий пристрій з металевим корпусом

Зміст Вступ до розподільчого пристрою KYN28-24 з металевим корпусом Застосування розподільчого пристрою KYN28-24 з металевим корпусом Ринкові тенденції та галузеві особливості Технічні характеристики KYN28-24 Умови експлуатації Первинний

Читати далі "