Unité principale annulaire XGN66-12

Introduction to XGN66-12 Ring Main Unit

In the evolving landscape of medium-voltage power distribution, Ring Main Units (RMUs) continue to play a crucial role by ensuring reliability, safety, and operational flexibility. The Unité principale annulaire XGN66-12 is a high-performance, metal-enclosed air-insulated appareillage de connexion designed for medium-voltage networks up to 12kV. Combining compactness, modularity, and superior operational safety, XGN66-12 offers outstanding solutions for modern energy systems.

XGN66-12 Ring Main Unit installed in a utility distribution room

Applications of XGN66-12 RMU

The XGN66-12 RMU is widely utilized in:

  • Urban and rural distribution networks
  • Industrial manufacturing facilities
  • Commercial buildings and shopping malls
  • Transportation infrastructure (airports, railway systems)
  • Renewable energy projects (solar, wind, hydropower plants)

Its versatility and resilience make it particularly valuable in environments where stability and uninterrupted power supply are paramount.

With the continuous expansion of urbanization and the growing need for decentralized energy systems, RMUs are becoming essential in modern grid architecture. According to IEEE and IEEMA reports, RMUs contribute significantly to enhancing the reliability and automation of secondary distribution networks (source).

Driven by the integration of smart grid technologies and increasing emphasis on sustainable energy, the market for compact, efficient switchgear like XGN66-12 continues to expand.

Technical Specifications of XGN66-12

Ring Main Unit Parameters

No.ObjetUnitéTechnical Data
1Rated voltagekV3.6 / 7.2 / 12
2Rated currentA630 / 1000 / 1250 / 2000 / 2500 / 3150
3Rated short-circuit breaking currentkA20 / 31.5 / 40
4Rated short-time withstand currentkA20 / 31.5 / 40
5Rated peak withstand currentkA50 / 80 / 100
6Rated short-circuit making currentkA50 / 80 / 100
7Duration of short circuits4
8Degree of protection-IP2X
9Bus system-Single bus, single bus with bypass, double bus
10Operating method-Electromagnetic / Spring mechanism
11Dimensions (W×D×H)mm950–1000 × 1000 × 2300 (for ≤1250A), 1000×1000×2300 (for >1250A)

Electrical Characteristics & Ratings

ParamètresUnitéValeur
Rated Working VoltageVAC400–AC690
Fréquence nominaleHz50 (60 optional)
Rated Insulation VoltageV660–800
1 min Power Frequency VoltagekV2500–3000
Control Motor PowerkW0–155
Courant nominal de courte duréekA15 / 30 / 50
Courant nominal de crête supportékA30 / 63 / 105
Degree of Protection-IP30
XGN66-12 RMU electrical characteristics and ratings chart

Principales caractéristiques et avantages

  • Flexible Busbar Configurations: Supports single bus, bypass bus, and double bus systems.
  • High Short-Circuit Capability: Rated for short-circuit breaking currents up to 40kA.
  • Compact Design: Minimal footprint without compromising performance.
  • Versatile Operating Mechanisms: Electromagnetic and spring-operated options.
  • Durable Protection: IP2X enclosure ensures personnel and system safety.
  • Ease of Integration: Designed for compatibility with SCADA and smart grid networks.

Comparaison avec d'autres types d'appareillage

FonctionnalitéXGN66-12 RMUXGN2-12 RMUSystèmes SIG
Isolation moyenneAirAirSF₆ Gaz
Application LevelSecondary DistributionSecondary DistributionPrimary / Secondary
SizeCompactCompactVery Compact
Maintenance NeedsLowModéréTrès faible
Typical UseUrban grids, IndustrialUrban grids, IndustrialSpace-constrained critical systems

Conseils pour la sélection et l'achat

When selecting the XGN66-12 Ring Main Unit, consider the following:

  • Voltage and Current Requirements
  • Grid Configuration Needs (single/double bus)
  • Short-circuit withstand capacity based on network protection requirements
  • Installation Space Constraints
  • Automation and Remote Monitoring Capabilities

Consulting with expert manufacturers like PINEELE ensures that the selected switchgear configuration aligns with both technical specifications and project-specific needs.

Foire aux questions (FAQ)

1. Qu'est-ce qui fait que le XGN66-12 RMU est adapté aux réseaux de distribution modernes ?

The XGN66-12 offers high fault tolerance, compact size, and flexibility in bus configurations, making it ideal for automated and resilient medium-voltage networks.

2. Can the XGN66-12 be customized for specific industrial applications?

Yes, the modular design allows customization in terms of current rating, bus system type, and operation methods to suit different industrial needs.

3. What is the typical lifespan of the XGN66-12 Ring Main Unit?

With proper installation and minimal maintenance, the XGN66-12 RMU can achieve a service life exceeding 30 years, providing reliable performance throughout its lifecycle.

Through advanced engineering, robust design, and a focus on operational safety and efficiency, PINEELE’s XGN66-12 Ring Main Unit delivers exceptional value and performance for medium-voltage power distribution networks.

GTXGN-12 Appareillage à gaine métallique

Table des matières Introduction à l'appareillage à gaine métallique GTXGN-12 Applications de l'appareillage GTXGN-12 Tendances du marché et contexte Spécifications techniques du GTXGN-12 Principales caractéristiques et avantages Comparaison

Lire la suite "

Unité principale annulaire XGN66-12

Table des matières Introduction à l'unité principale à anneau XGN66-12 Applications de l'unité principale à anneau XGN66-12 Tendances du marché et contexte Spécifications techniques des paramètres de l'unité principale à anneau XGN66-12

Lire la suite "

SRM6-12 Appareillage à isolation gazeuse

Table des matières Introduction à l'appareillage de commutation à isolation gazeuse SRM6-12 Applications du SRM6-12 SIG Tendances du marché et contexte Spécifications techniques du SRM6-12 Principales caractéristiques et avantages Comparaison

Lire la suite "

KYN28-24 Appareillage à gaine métallique

Table des matières Introduction à l'appareillage à gaine métallique KYN28-24 Applications de l'appareillage à gaine métallique KYN28-24 Tendances du marché et contexte industriel Spécifications techniques du KYN28-24 Conditions de fonctionnement Primaire

Lire la suite "

XGN2-12 Unité principale de l'anneau (RMU)

Table des matières Introduction à l'unité principale à anneau XGN2-12 Applications de l'unité principale à anneau XGN2-12 Tendances du marché et contexte Spécifications techniques de l'unité principale à anneau XGN2-12 Principales caractéristiques de l'unité principale à anneau XGN2-12

Lire la suite "