KYN28-24 Appareillage à gaine métallique

Introduction to KYN28-24 Metal-Clad Switchgear

In the realm of medium-voltage power distribution, metal-clad switchgear plays a vital role in enhancing network reliability, safety, and operational flexibility. The KYN28-24 Appareils de commutation à enveloppe métallique is a state-of-the-art air-insulated switchgear solution engineered for primary distribution networks. Designed with modularity, durability, and high performance in mind, it serves critical infrastructure projects across industrial, utility, and renewable sectors.

Front view of KYN28-24 Metal-Clad Switchgear installed in an industrial substation

Applications of KYN28-24 Metal-Clad Switchgear

The KYN28-24 switchgear is ideal for a wide range of demanding environments, including:

  • Primary substations in power grids
  • Large-scale industrial complexes and manufacturing plants
  • Mining operations and petrochemical facilities
  • Renewable energy installations (wind farms, solar stations)
  • Infrastructure projects (airports, data centers, hospitals)

Its high short-circuit handling capability and robust mechanical endurance make it particularly suited for mission-critical systems that require absolute reliability.

The transition towards smarter grids, electrification of transportation, and increased focus on energy resilience have fueled the demand for advanced medium-voltage switchgear globally. According to an IEEE report, the global switchgear market is projected to grow steadily as industries modernize existing grids and integrate more renewable energy (source).

Metal-clad switchgear like the KYN28-24 remains indispensable due to its exceptional safety features, flexibility for future upgrades, and superior compartmentalization.

Technical Specifications of KYN28-24

Operating Conditions

ConditionSpécifications
Température ambiante+15°C to +40°C (avg ≤35°C in 24h)
Altitude≤1000m
Relative HumidityMonthly avg ≤90%, vapor pressure ≤1.8kPa
Dust, Smoke, GasesNo corrosive, flammable, or conductive pollution
Vibration / Ground MotionNegligible
Electromagnetic Interference≤1.6kV induced in secondary circuits
Environmental operating conditions chart for KYN28-24 switchgear

Primary Technical Specifications

ObjetUnitéData
Tension nominalekV24
Fréquence nominaleHz50 / 60
Lightning Impulse Withstand Voltage (phase, ground)kV60
Lightning Impulse Withstand Voltage (isolator)kV79
Power Frequency Withstand Voltage (phase, ground)kV125
Power Frequency Withstand Voltage (isolator)kV145
Auxiliary Circuit Withstand VoltageV2000
Rated Circuit Breaker CurrentA630 / 1250 / 1600 / 2000 / 2500 / 3150
Short-Circuit Breaking CurrentkA20 / 31.5
Short-Circuit Closing Current (Peak)kA50 / 80
Short-Time Withstand CurrentkA20 / 31.5
Courant de crête supportékA50 / 80
Auxiliary Circuit VoltageVAC/DC 110 / 220
Degré de protection-IP4X (IP2X with door open)
Dimensions (L×P×H)mm800×1810×2380 / 1000×1810×2380
Weightkg840 ~ 1140
Detailed technical specifications table for KYN28-24 Metal-Clad Switchgear

Principales caractéristiques et avantages

  • Superior Compartmentalization: Fully metal-clad and isolated compartments improve personnel and system safety.
  • Flexible Configurations: Modular design allows for easy system expansions and retrofits.
  • High Fault Tolerance: Capable of handling up to 31.5kA short-circuit currents.
  • Enhanced Durability: Designed for long mechanical life even under frequent switching operations.
  • Ease of Maintenance: Logical layout with front access reduces maintenance time and enhances safety.

VS1-24 Vacuum Circuit Breaker Overview

The VS1-24 Vacuum Circuit Breaker is the core switching component used inside the KYN28-24 switchgear, offering exceptional breaking performance and mechanical endurance.

VS1-24 Key Technical Parameters

ObjetUnitéData
Tension nominalekV24
Lightning Impulse WithstandkV60
Power Frequency WithstandkV125
Fréquence nominaleHz50 / 60
Courant nominalA630–3150
Short-Circuit Breaking CurrentkA20 / 31.5
Closing Current (Peak)kA50 / 80
Short-Time Withstand CurrentkA20 / 31.5
Courant de crête supportékA50 / 80
Capacitor Bank Breaking (single/back-to-back)A630 / 400
Breaking Operation TimesTemps50
Mechanical LifeTemps20,000
Operating Sequence-O-0.3s-CO-180s-CO
VS1-24 Vacuum Circuit Breaker specifications integrated within KYN28-24 switchgear

Comparaison avec d'autres types d'appareillage

FonctionnalitéKYN28-24 Metal-CladGIS (Gas-Insulated Switchgear)Air-Insulated RMU
Isolation moyenneAirSF₆ GazAir
Niveau d'applicationPrimaryPrimarySecondary
FootprintPlus grandTrès compactCompact
MaintenanceModéréTrès faibleFaible
Environmental SensitivityModéréFaibleHigh

Conseils pour la sélection et l'achat

When selecting KYN28-24 switchgear, key considerations include:

  • System Voltage and Short-Circuit Level Requirements
  • Space Availability and Accessibility
  • Integration Needs with Protection Relays and Automation
  • Compliance with IEC, GB, and Local Standards

Engaging with expert engineers from PINEELE ensures that the switchgear selection perfectly aligns with project-specific technical and operational needs.

Foire aux questions (FAQ)

1. What industries most commonly use KYN28-24 Metal-Clad Switchgear?

KYN28-24 is widely adopted in utilities, heavy industries, transportation infrastructure, and renewable energy projects requiring medium-voltage primary distribution.

2. Can the KYN28-24 switchgear be customized for special operating environments?

Yes. Customized designs for harsh environments, seismic zones, or specific temperature/humidity conditions are available based on project requirements.

3. How long is the typical operational lifespan of KYN28-24 switchgear?

With proper maintenance, the mechanical lifespan exceeds 20 years, supported by the 20,000 mechanical operation cycles of its VS1-24 vacuum circuit breaker.

PINEELE’s KYN28-24 Metal-Clad Switchgear stands as a benchmark for performance, safety, and reliability in medium-voltage power distribution systems worldwide.

TBB Armoire de compensation de haute tension

Table des matières Comprendre le concept de base Applications dans les réseaux électriques modernes Spécifications techniques Tendances de l'industrie et évolution technologique Différences par rapport aux autres produits

Lire plus "

GTXGN-12 Appareillage à gaine métallique

Table des matières Introduction à l'appareillage à gaine métallique GTXGN-12 Applications de l'appareillage GTXGN-12 Tendances du marché et contexte Spécifications techniques du GTXGN-12 Principales caractéristiques et avantages Comparaison

Lire plus "

Unité principale annulaire XGN66-12

Table des matières Introduction à l'unité principale à anneau XGN66-12 Applications de l'unité principale à anneau XGN66-12 Tendances du marché et contexte Spécifications techniques des paramètres de l'unité principale à anneau XGN66-12

Lire plus "

SRM6-12 Appareillage à isolation gazeuse

Table des matières Introduction à l'appareillage de commutation à isolation gazeuse SRM6-12 Applications du SRM6-12 SIG Tendances du marché et contexte Spécifications techniques du SRM6-12 Principales caractéristiques et avantages Comparaison

Lire plus "

KYN28-24 Appareillage à gaine métallique

Table des matières Introduction à l'appareillage à gaine métallique KYN28-24 Applications de l'appareillage à gaine métallique KYN28-24 Tendances du marché et contexte industriel Spécifications techniques du KYN28-24 Conditions de fonctionnement Primaire

Lire plus "

XGN2-12 Unité principale de l'anneau (RMU)

Table des matières Introduction à l'unité principale à anneau XGN2-12 Applications de l'unité principale à anneau XGN2-12 Tendances du marché et contexte Spécifications techniques de l'unité principale à anneau XGN2-12 Principales caractéristiques de l'unité principale à anneau XGN2-12

Lire plus "