XGN66-12 Unidad principal de anillo

Introduction to XGN66-12 Ring Main Unit

In the evolving landscape of medium-voltage power distribution, Ring Main Units (RMUs) continue to play a crucial role by ensuring reliability, safety, and operational flexibility. The XGN66-12 Unidad principal de anillo is a high-performance, metal-enclosed air-insulated aparamenta designed for medium-voltage networks up to 12kV. Combining compactness, modularity, and superior operational safety, XGN66-12 offers outstanding solutions for modern energy systems.

XGN66-12 Ring Main Unit installed in a utility distribution room

Applications of XGN66-12 RMU

The XGN66-12 RMU is widely utilized in:

  • Urban and rural distribution networks
  • Industrial manufacturing facilities
  • Commercial buildings and shopping malls
  • Transportation infrastructure (airports, railway systems)
  • Renewable energy projects (solar, wind, hydropower plants)

Its versatility and resilience make it particularly valuable in environments where stability and uninterrupted power supply are paramount.

With the continuous expansion of urbanization and the growing need for decentralized energy systems, RMUs are becoming essential in modern grid architecture. According to IEEE and IEEMA reports, RMUs contribute significantly to enhancing the reliability and automation of secondary distribution networks (source).

Driven by the integration of smart grid technologies and increasing emphasis on sustainable energy, the market for compact, efficient switchgear like XGN66-12 continues to expand.

Technical Specifications of XGN66-12

Ring Main Unit Parameters

No.ItemUnitTechnical Data
1Rated voltagekV3.6 / 7.2 / 12
2Rated currentA630 / 1000 / 1250 / 2000 / 2500 / 3150
3Rated short-circuit breaking currentkA20 / 31.5 / 40
4Rated short-time withstand currentkA20 / 31.5 / 40
5Rated peak withstand currentkA50 / 80 / 100
6Rated short-circuit making currentkA50 / 80 / 100
7Duration of short circuits4
8Degree of protectionIP2X
9Bus systemSingle bus, single bus with bypass, double bus
10Operating methodElectromagnetic / Spring mechanism
11Dimensions (W×D×H)mm950–1000 × 1000 × 2300 (for ≤1250A), 1000×1000×2300 (for >1250A)

Electrical Characteristics & Ratings

ParámetroUnitValor
Rated Working VoltageVAC400–AC690
Frecuencia nominalHz50 (60 optional)
Rated Insulation VoltageV660–800
1 min Power Frequency VoltagekV2500–3000
Control Motor PowerkW0–155
Rated Short-Time Withstand CurrentkA15 / 30 / 50
Rated Peak Withstand CurrentkA30 / 63 / 105
Degree of ProtectionIP30
XGN66-12 RMU electrical characteristics and ratings chart

Key Features and Benefits

  • Flexible Busbar Configurations: Supports single bus, bypass bus, and double bus systems.
  • High Short-Circuit Capability: Rated for short-circuit breaking currents up to 40kA.
  • Compact Design: Minimal footprint without compromising performance.
  • Versatile Operating Mechanisms: Electromagnetic and spring-operated options.
  • Durable Protection: IP2X enclosure ensures personnel and system safety.
  • Ease of Integration: Designed for compatibility with SCADA and smart grid networks.

Comparison with Other Switchgear Types

FeatureXGN66-12 RMUXGN2-12 RMUGIS Systems
Insulation MediumAirAirSF₆ Gas
Application LevelSecondary DistributionSecondary DistributionPrimary / Secondary
SizeCompactCompactVery Compact
Maintenance NeedsLowModerateVery Low
Typical UseUrban grids, IndustrialUrban grids, IndustrialSpace-constrained critical systems

Selection and Purchase Guidance

When selecting the XGN66-12 Ring Main Unit, consider the following:

  • Voltage and Current Requirements
  • Grid Configuration Needs (single/double bus)
  • Short-circuit withstand capacity based on network protection requirements
  • Installation Space Constraints
  • Automation and Remote Monitoring Capabilities

Consulting with expert manufacturers like PINEELE ensures that the selected switchgear configuration aligns with both technical specifications and project-specific needs.

Frequently Asked Questions (FAQ)

1. What makes the XGN66-12 RMU suitable for modern distribution networks?

The XGN66-12 offers high fault tolerance, compact size, and flexibility in bus configurations, making it ideal for automated and resilient medium-voltage networks.

2. Can the XGN66-12 be customized for specific industrial applications?

Yes, the modular design allows customization in terms of current rating, bus system type, and operation methods to suit different industrial needs.

3. What is the typical lifespan of the XGN66-12 Ring Main Unit?

With proper installation and minimal maintenance, the XGN66-12 RMU can achieve a service life exceeding 30 years, providing reliable performance throughout its lifecycle.

Through advanced engineering, robust design, and a focus on operational safety and efficiency, PINEELE’s XGN66-12 Ring Main Unit delivers exceptional value and performance for medium-voltage power distribution networks.

Aparamenta metálica GTXGN-12

Tabla de contenidos Introducción a la aparamenta metálica GTXGN-12 Aplicaciones de la aparamenta GTXGN-12 Tendencias del mercado y antecedentes Especificaciones técnicas de GTXGN-12 Comparación de características y ventajas principales

Leer Más "

XGN66-12 Unidad principal de anillo

Índice Introducción a la unidad principal de anillo XGN66-12 Aplicaciones de la RMU XGN66-12 Tendencias del mercado y antecedentes Especificaciones técnicas de los parámetros de la unidad principal de anillo XGN66-12

Leer Más "

Aparamenta aislada en gas SRM6-12

Tabla de contenidos Introducción a la aparamenta aislada en gas SRM6-12 Aplicaciones de SRM6-12 Tendencias y antecedentes del mercado GIS Especificaciones técnicas de SRM6-12 Comparación de características y ventajas principales

Leer Más "

KYN28-24 Aparamenta metálica

Tabla de contenidos Introducción a la aparamenta metálica KYN28-24 Aplicaciones de la aparamenta metálica KYN28-24 Tendencias del mercado y antecedentes industriales Especificaciones técnicas de KYN28-24 Condiciones de funcionamiento Primarias

Leer Más "

XGN2-12 Unidad principal de anillo (RMU)

Tabla de contenidos Introducción a la unidad principal de anillo XGN2-12 Aplicaciones de la unidad principal de anillo XGN2-12 Tendencias del mercado y antecedentes Especificaciones técnicas de XGN2-12 RMU Clave

Leer Más "